A standard-current 1500 V DC smart combiner box for 12–24 PV inputs, with up to 25 A per input, dual-pole fusing and 250 / 400 / 500 / 630 A output configurations. In-house monitoring, active protection and broadcast tripping are standard in an IP65 outdoor enclosure.
A standard-current 1500 V DC smart combiner box for 12–24 PV inputs, with up to 25 A per input, dual-pole fusing and 250 / 400 / 500 / 630 A output configurations. In-house monitoring, active protection and broadcast tripping are standard in an IP65 outdoor enclosure.
Where it fits
Standard-current PV DC combining for large-scale PV plants, with 12-24 inputs and 250 / 400 / 500 / 630 A output configurations.
Key features
In-house monitoring and control CFGE develops the current and voltage monitoring modules and tripping controls in-house, integrating string monitoring, short-circuit protection and active protection.
12-24 inputs with dual-pole fusing Up to 25 A per input, with positive and negative poles fused. The standard fuse rating is 32 A; 30 A and 35 A are optional.
Active and broadcast tripping as standard Bus short-circuit and active protection, active and broadcast tripping, energy and power monitoring, and reverse-current protection are standard. Active fire suppression is optional.
IP65 outdoor enclosure Wall mounting or horizontal installation, operating from -25 to +60 °C with no altitude derating up to 2,000 m.
Specifications+
Electrical Specifications
Maximum input voltage
1,500 V DC
Number of input circuits
12-24 inputs
Maximum current per input
25 A
Maximum output current
250 / 400 / 500 / 630 A
Fuse protection polarity
Positive and negative poles fused (dual-pole fusing)
Fuse rated voltage
1,500 V DC
Fuse breaking capacity
20 / 30 kA
Fuse rated current
32 A standard; 30 A / 35 A optional
Environment and Installation
Operating temperature
-25 to +60 °C
Storage temperature
-30 to +70 °C
Relative humidity
99%, non-condensing
Operating altitude
≤ 2,000 m, no derating
Ingress protection
IP65
Mounting
Wall mounting / horizontal installation
Protection and Monitoring
Switch configuration
Breaker or load switch
Switch voltage and current
1,500 V DC / 250 / 400 / 500 / 630 A
Switch operation
Internal / external handle with door interlock and LOTO
SPD configuration
Type I+II standard; Type I / Type II optional
SPD rated voltage
1,500 V DC
Maximum continuous voltage
1,800 V DC
Discharge current
20 / 40 kA (8/20 μs)
Voltage protection level
≤ 5.5 kV
Current and voltage monitoring
Each input string current / busbar voltage
Switch and SPD status
Standard
Communication and protocol
RS485 Modbus-RTU / Wireless / HPLC
Current sensing
Shunt resistor / Hall sensor
Monitoring power supply
Self-powered Input: 300-1,600 V DC Output: 0-5 V / 24 V DC
Smart Function Configuration
Bus short-circuit and active protection
Standard
Active and broadcast tripping
Standard
Energy and power monitoring
Standard
Reverse-current protection
Standard
Active fire suppression
Optional
Standards and Certifications
Standards listed in the data sheet
IEC 61439-1/2, IEC 62109-1, EN 61000-6, UL 1741, AS 3000, AS 5033, GB/T 34936
Specifications from the CFGE 1500 V DC Smart Combiner Box 12-24 Inputs data sheet, Standard Current Version. Confirm the input count, output rating, fuse configuration and market requirements with sales before ordering.
Datasheet+
The bilingual English / Chinese datasheet downloads directly as PDF. No registration needed.